CHALLENGER III
The Challenger III uses a Russian GS35 ceramic triode valve.
This is a very rugged valve,which is capable of producing high power for long operating periods.
The Challenger will cover all the HF bands,10-160m with separate band positions for the WARC bands.
There is a massive 2.2kVA toroidal transformer producing 3600V after the voltage doubler board.
Cooling is forced air from a Papst flatpack blower located just under the transformer.
The Challenger III features a newly designed control board, which provides protection for grid over-current, plate over-current, over-drive and internal valve flash-over.
It also provides soft-start,warm-up timer,sequenced relays and high speed switching relay.
Specifications
Output
power |
1500W SSB or CW Max,
1000W RTTY Max |
| Gain |
13dB
nominal |
Power
requirements |
230V AC
at 13A, 50/60 Hz |
Frequency
coverage |
All
amateur bands 1.8 - 29.7MHz |
| Valve |
single
GS35b ceramic triode |
DC
voltage |
3600V DC |
| Metering |
Plate
current, Grid current/RF O/P |
|
Dimensions |
16in wide
x 9.5in high x 17in deep 410mm x 240mm x 475mm |
| Weight |
29kg |
Please contact us for pricing and delivery information.
Under the Cover
Created on 04/11/2005 11:27 AM by linampadmin
Updated on 04/08/2009 03:20 PM by Paul
|
|